Current Position:Home>>Technical Questions
1) What is Access Control System?
 

Re: Access control system refers to thepractice of restricting entrance to a property, a building, or a room toauthorized persons. Physical access control can be achieved by a human (aguard, bouncer, or receptionist), through mechanical means such as locks andkeys, or through technological means such as access control systems.
Physical access control is a matter of who,where, and when. An access control system determines who is allowed to enter orexit, where they are allowed to exit or enter, and when they are allowed toenter or exit.

2) 
Access system password is entered butunable to enter into various functional selection of the setting mode 

Re: 
1.Incomplete input of system password,please check if correct format *XXXX # (XXXX as system password) has been entered as required in manual.
2.System password has been changed. Inquirereaders parameterto get the password if it is networking reader. Contact your nearby agent orreturn to the manufacturer if it is stand-alone reader.
3.Bad wire arrangement which might causeshort circuit of the PC board. Check the power supply and the control wires inorder to avoid the wires pressing on the PC board causing bad contact, shortcircuit and interference.
4.Strong interference from other equipmentsor same type unit caused the new unit is unable to enter Setting Mode or slowresponse from the keypad. Move the new unit to other place to test again.


3) How Magnetic Locks Work ? 

Re: A magnetic lock, often referred to as a mag lock, consists of an electromagnet and an armature plate. 
The magnet is mounted inside of the door opening, which prevents tampering, while the plate is installed on the face of the door. 
When the magnet is connected to an electrical source, it produces a strong magnetic attraction that holds the magnet tight to the plate, effectively locking the door. The lock is typically powered using either the building's electrical system or a separate battery pack. Because a mag lock can only be used with DC power, a converter unit must be added when relying on building power.  These locks are said to be "fail-safe," meaning that once the power goes out, the door will remain unlocked, allowing occupants to exit safely.

4) How to stop anti-damage activation or duress alarm activation?

Re:1.RFID the card and open the door asregular basis again to turn it off.
2.Check the activation of the alarm forsecurity purposes.
3.When the alarm is still on and thenetwork software shows the unit is being tampered which means the anti-tamperswitch is not closely mounted onto the wall.

5) What is the communication protocol for UHF readers
 
Re:Default reader has wiegand26 output,RS232 or RS485 communication protocol.
TCP IP  or Wifi can be customized.